BRC1C62 ED39-634
54 Wired Remote Controller
Note:
1. Setting is carried out in the group mode, however, set the mode number inside the ( ) for individual
setting of the each indoor unit or confirmation after setting.
2. The SECOND CODE number is set to “01” when shipped from the factory.
However for the following cases it is set to “02”.
$Air flow direction range setting.
3. Do not make any settings not given in the table above.
4. Not displayed if the indoor unit is not equipped with that function.
5. When returning to the normal mode, “88” may be displayed in the LCD in order for the remote controller to
initialize itself.
2P068938-1
FIELD SETTING
If optional accessories are mounted on the indoor unit, the
indoor unit setting may have to be changed. Refer to the
instruction manual for each optional accessory.
Procedure
When in the normal mode, press the ” button for a minimum of four seconds,
and the FIELD SET MODE is entered.
TEST
TEST
Select the desired MODE NO. with the ” button.
During group control, when setting by each indoor unit (mode No. 20, 21 and 23
have been selected), push the ” button and select the INDOOR UNIT NO to
be set. (This operation is unnecessary when setting by group.)
Push the ” upper button and select FIRST CODE NO.
Push the ” lower button and select the SECOND CODE NO.
Push the ” button once and the present settings are SET.
Push the ” button for about one second to return to the NORMAL MODE.
(Example) If during group setting and the time to clean air filter is set to FILTER CONTAMINATION -
HEAVY, SET MODE NO. to “10,FIRST CODE NO. to “0,” and SECOND CODE NO to “02.”
Mode No.
Note) 1
FIRST
CODE NO.
Description of Setting
SECOND CODE No. Note) 2
01
Ultra-long-life type
Long-life type
Standard type
Long-life filter
Light
Heavy
0
Long-life filter type (Setting of filter sign indication time)
(Change setting when Ultra-long-life filter is installed)
Approx. 10,000 hours
Approx. 2,500 hours
Approx. 200 hours
Approx. 5,000 hours
Approx. 1,250 hours
Approx. 100hours
02
Setting Number of Connected Skyair Simultaneous Operation System
Indoor Units(Setting for Simultaneous Operation System)
Spacing Time of Display Time to Clean Air Filter Count
(Setting for when the filter sign is not to be displayed)
High Celling Setting
(Setting for when installed in a Ceiling higher than 2.7m)
Selection of Air Flow Direction (Setting for when a blocking pad kit has
been installed)
Air Flow Direction Adjust Function
(To be set when decoration panel for air outlet is installed)
Air Flow Direction Range Setting
Setting the External Static Pressure
(Setting according to the connected duct resistance)
(For FHYK, follow the High Ceiling Setting)
Display
Pair
Normal
F
Equippeed
Upper
Normal
(Normal)
Ultra-long-life filter (1)
Do Not Display
Twin
High Ceiling 1
T
No Equippeed
Normal
High Static Pressure
(High Ceiling)
Low Static Pressure
Lower
High Ceiling 2
W
03
1
3
0
0
1
3
4
6
10(20)
11(21)
13(23)
SETTING
TEST
UNIT NO.
3
4
5
6
7
1
2
FIELD
SET
MODE
UNIT NO.
.
SECOND
CODE NO.
.
MODE NO.
FIRST
CODE NO.
.
Filter Contamination - Heavy/Light
(Setting for spacing time of display time to clean air filter)
(Setting for when filter contamination is heavy, and
spacing time to clean air filter is to be halved)