Seitenansicht 0
SPLIT SYSTEM Air Conditioners
INSTALLATION MANUAL
READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.
KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.
LESEN SIE DIESE ANWEISUNGEN VOR DER INSTALLATION SORGFÄLTIG DURCH.
BEWAHREN SIE DIESE ANLEITUNG FÜR SPÄTERE BEZUGNAHME GRIFFBEREIT AUF.
LIRE SOIGNEUSEMENT CES INSTRUCTIONS AVANT L’INSTALLATION.
CONSERVER CE MANUEL A PORTEE DE MAIN POUR REFERENCE ULTERIEURE.
LEA CUIDADOSAMENTE ESTAS INSTRUCCIONES ANTES DE INSTALAR.
GUARDE ESTE MANUAL EN UN LUGAR A MANO PARA LEER EN CASO DE TENER ALGUNA DUDA.
PRIMA DELL’INSTALLAZIONE LEGGERE ATTENTAMENTE QUESTE ISTRUZIONI.
TENERE QUESTO MANUALE A PORTATA DI MANO PER RIFERIMENTI FUTURI.
ÄΙΑΒΑΣΤΕ ΠΡΟΣΕΚΤΙΚΑ ΑΥΤΕΣ ΤΙΣ ΟÄΗΓΙΕΣ ΠΡΙΝ ΑΠΟ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ ΕΧΕΤΕ ΑΥΤΟ
ΤΟ ΕΓΧΕΙΡΙÄΙΟ ΕΥΚΑΙΡΟ ΓΙΑ ΝΑ ΤΟ ΣΥΜΒΟΥΛΕΥΕΣΤΕ ΣΤΟ ΜΕΛΛΟΝ.
LEES DEZE INSTRUCTIES ZORGVULDIG DOOR VOOR INSTALLATIE. BEWAAR DEZE HAN-
DLEINDING WAAR U HEM KUNT TERUGVINDEN VOOR LATERE NASLAG.
LEIA COM ATENÇÃO ESTAS INSTRUÇÕES ANTES DE REALIZAR A INSTALAÇÃO.
MANTENHA ESTE MANUAL AO SEU ALCANCE PARA FUTURAS CONSULTAS.
ПЕРЕД НАЧАЛОМ МОНТАЖА ВНИМАТЕЛЬНО ОЗНАКОМЬТЕСЬ С ДАННЫМИ
ИНСТРУКЦИЯМИ. СОХРАНИТЕ ДАННОЕ РУКОВОДСТВО В МЕСТЕ, УДОБНОМ ДЛЯ
ОБРАЩЕНИЯ В БУДУЩЕМ.
MODELS
(Ceiling suspension type)
FH(Y)35BJV1 FHYP35BV1 FH35BZV1 FHQ35BUV1B FHQ35BVV1B
FH(Y)45BJV1 FHYP45BV1 FH45BZV1 FHQ50BUV1B FHQ50BVV1B
FH(Y)60BJV1 FHYP60BV1 FH60BZV1 FHQ60BUV1B FHQ60BVV1B
FHY71BJV1 FHYP71BV1 FHQ71BUV1B FHQ71BVV1B
FHY100BJV1 FHYP100BV1 FHQ100BUV1B FHQ100BVV1B
FHY125BJV1 FHYP125BV1 FHQ125BUV1B FHQ125BVV1B
English
Deutsch
Français
Español
Italiano
Nederlands
Portugues
00_CV_3PN06588-3H.fm Page 1 Monday, April 6, 2009 7:49 PM
Seitenansicht 0
1 2 3 4 5 6 ... 31 32

Inhaltsverzeichnis

Seite 1 - INSTALLATION MANUAL

SPLIT SYSTEM Air ConditionersINSTALLATION MANUALREAD THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION.KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REF

Seite 2 - Machinery Safety 98/37/EC

8 English5. INDOOR UNIT INSTALLATIONIt may be easier to attach accessory parts before installing the indoor unit. Therefore, please also read the inst

Seite 3 - 1. SAFETY PRECAUTIONS

English 96. REFRIGERANT PIPING WORK〈For refrigerant piping of outdoor units, see the installation manual attached to the outdoor unit.〉 〈Execute heat

Seite 4

10 EnglishNot recommendable but in case of emergencyYou must use a torque wrench but if you are obliged to install the unit without a torque wrench, y

Seite 5 - 2. BEFORE INSTALLATION

English 11• Make absolutely sure to execute heat insulation works on the pipe-connecting section after checking gas leakage by thoroughly studying the

Seite 6 - 2-3 NOTE TO THE INSTALLER

12 English(1) For piping facing back.• Remove the rear penetration lid and set the piping. (Refer to Fig. 14.16)(2) For piping facing up.• When settin

Seite 7 - ∗≥30 ∗≥30

English 137. DRAIN PIPING WORK(1) Carry out the drain piping.• Make sure piping provides proper drainage.• You can select whether to bring the drain p

Seite 8

14 English• Insulate the clamp bracket and drain hose from the bottom using the included sealing pad (8). (Refer to Fig. 21)• Be sure to insulate all

Seite 9

English 158. WIRING EXAMPLEFor the wiring of outdoor units, refer to the installation manual attached to the outdoor units.Confirm the system type.• P

Seite 10 - 5. INDOOR UNIT INSTALLATION

16 EnglishNOTE1.All transmission wiring except for the remote controller wires is polarized and must match the terminal symbol.2. In case of group con

Seite 11 - 6. REFRIGERANT PIPING WORK

English 17Connection of wiring between units and for the remote control cord (Refer to Fig. 27)• Wiring between unitsHolding the control box lid, loo

Seite 12

Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,Kita-ku, Osaka, 530-8323 JapanDAIKIN INDUSTRIES, LTD.EN60335-2-40,3P104327-1FShinri SadaManager Quality Con

Seite 13

18 EnglishObserve the notes mentioned below when wiring to the terminals.Tightening torque for the terminal screws.• Use the correct screwdriver for t

Seite 14

English 1910. FIELD SETTINGS(1) Make sure the control box lids are closed on the indoor and outdoor units.(2) Field settings must be made from the rem

Seite 15 - 7. DRAIN PIPING WORK

20 EnglishWhen using wireless remote controllers• When using wireless remote controllers, wireless remote controller address setting is necessary. Ref

Seite 16

English 2110-7 Two remote controllers control (Controlling 1 indoor unit by 2 remote controllers)• When using 2 remote controllers, one must be set to

Seite 17 - 8. WIRING EXAMPLE

22 EnglishPRECAUTIONS1. Refer to “11-2 HOW TO DIAGNOSE FOR MALFUNCTION” if the unit does not operate properly.2. After completing the test run, press

Seite 18 - 9. ELECTRIC WIRING WORK

English 2311-3 Malfunciton code• For places where the malfunction code is left blank, the “ ” indication is not displayed. Though the system continues

Seite 19

24 English12. WIRING DIAGRAM(Refer to Fig. 34.35.36.37.38)LC Transmission malfunction between the outdoor control units’ inverters (outdoor)P1 Open-ph

Seite 20 - Attach insulation sleeve

English 25: CONNECTOR3D027501-1 FH35 • 50 • 60 • 71 • 100 • 125BVE, FH71 • 100 • 125BV1S, FH35 • 45 • 60BJV1, FH35 • 45 • 60BZV133AA1PA2PC1RF1UHAPM1AM

Seite 21 - 10. FIELD SETTINGS

26 English3D027502-1 FHY35 • 50 • 60 • 71 • 100 • 125BVE, FHY35 • 45 • 60 • 71 • 100 • 125BJV133AA1PC1RHAPHBPM1AM1FQ1FR1TR2TRyARyPSS1T1RX1MX2M PC RC

Seite 22 - Indoor unit 3

English 27: CONNECTOR3D027503-1 FHYP35 • 45 • 60 • 60 • 71 • 100 • 125BV133AA1PC1RHAPHBPM1AM1FQ1FR1TR2TRyARyPSS1T1RX1MX2M PC RC TCLIMIT SWITCH (SWI

Seite 23 - 11. TEST OPERATION

English 1FH(Y)35BJV1FH(Y)45BJV1FH(Y)60BJV1FHY71BJV1FHY100BJV1FHY125BJV1FHYP35BV1FHYP45BV1FHYP60BV1FHYP71BV1FHYP100BV1FHYP125BV1FH35BZV1FH45BZV1FH60BZV

Seite 24

28 English, : CONNECTOR3D037842-1D FHQ35 • 50 • 60 BUV1B, FHQ35 • 50 • 60BVV1BA1PC1F1UHAPKARKPRM1FM1SQ1MR1TR2TR3TS1QT1RV1TRX1MX2M RC TCW

Seite 25 - 11-3 Malfunciton code

English 29, : CONNECTOR3D043825-1B FHQ71 • 100 • 125 BAV3B, FHQ71 • 100 • 125 BUV1B, FHQ71 • 100 • 125BVV1BA1PC1HAPKARKPRM1FM1SQ1MR1TR2TS1

Seite 26 - 12. WIRING DIAGRAM

(0905)HT3PN06588-3H EM02A060H00_CV_3PN06588-3H.fm Page 2 Monday, April 6, 2009 7:49 PM

Seite 27 - WIRING DIAGRAM

2 English• Install the air conditioner on a foundation strong enough to withstand the weight of the unit.A foundation of insufficient strength may res

Seite 28

English 32. BEFORE INSTALLATION• When moving the unit while removing it from the carton box, be sure to lift it by holding on to the four lifting lugs

Seite 29

4 EnglishNOTE• If you wish to use a remote controller that is not listed in “Table 1” on page 3, select a suitable remote con-troller after consulting

Seite 30

English 53. SELECTING INSTALLATION SITE(1) Select an installation site where the following conditions are fulfilled and that meets your cus-tomer’s ap

Seite 31

6 English4. PREPARATIONS BEFORE INSTALLATION(1) Relation of holes for indoor unit, suspension bolt position, piping and wiring.(2) Make holes for susp

Seite 32 - 3PN06588-3H EM02A060H

English 7(3-3) Remove the hanger brackets.• Loosen the 2 bolts (M8) used to attach the hanger brackets which are on each side (4 places left and right