Table of Contents iii
2.17 “E6” Standard Compressor Motor Overcurrent/Lock.............................137
2.18 “E7” Malfunction of Outdoor Unit Fan Motor..........................................138
2.19 “E9” Outdoor Unit: Malfunction of Moving Part of Electronic Expansion
Valve (Y1E, Y2E) .................................................................................140
2.20 “F3” Outdoor Unit: Abnormal Discharge Pipe Temperature ..................142
2.21 “F6” Refrigerant Overcharged ...............................................................143
2.22 “H7” Abnormal Outdoor Fan Motor Signal .............................................144
2.23 “H9” Outdoor Unit: Malfunction of Thermistor for Outdoor Air (R1T).....145
2.24 “J2” Current Sensor Malfunction...........................................................146
2.25 “J3” Outdoor Unit: Malfunction of Discharge Pipe Thermistor
(R31 or 32T) .........................................................................................147
2.26 “J5” Outdoor Unit: Malfunction of Thermistor (R2T) for Suction Pipe ...148
2.27 “J6” Outdoor Unit: Malfunction of Thermistor (R4T) for
Outdoor Unit Heat Exchanger ..............................................................149
2.28 “J9” Malfunction of Receiver Gas Pipe Thermistor (R5T).....................150
2.29 “JA” Outdoor Unit: Malfunction of High Pressure Sensor......................151
2.30 “JC” Outdoor Unit: Malfunction of Low Pressure Sensor.......................152
2.31 “L4” Outdoor Unit: Malfunction of Inverter Radiating Fin
Temperature Rise.................................................................................153
2.32 “L5” Outdoor Unit: Inverter Compressor Abnormal ...............................154
2.33 “L8” Outdoor Unit: Inverter Current Abnormal.......................................155
2.34 “L9” Outdoor Unit: Inverter Start up Error..............................................156
2.35 “LC” Outdoor Unit: Malfunction of Transmission between Inverter
and Control PC Board ..........................................................................157
2.36 “P1” Outdoor Unit: Inverter Over-Ripple Protection ...............................159
2.37 “P4” Outdoor Unit: Malfunction of Inverter Radiating Fin
Temperature Rise Sensor ....................................................................160
2.38 “PJ” Outdoor Unit: Faulty Field Setting after Replacing
Main PC Board or Faulty Combination of PC Board ............................161
2.39 “UO” Low Pressure Drop Due to Refrigerant Shortage or
Electronic Expansion Valve Failure......................................................162
2.40 “U1” Reverse Phase, Open Phase.........................................................163
2.41 “U2” Power Supply Insufficient or Instantaneous Failure ......................164
2.42 “U3” Check Operation not Executed......................................................166
2.43 “U4” Malfunction of Transmission between Indoor Units.......................167
2.44 “U5” Malfunction of Transmission between Remote Controller
and Indoor Unit.....................................................................................169
2.45 “U7” Malfunction of Transmission between Outdoor Units ....................170
2.46 “U8” Malfunction of Transmission between MAIN and
SUB Remote Controllers ......................................................................172
2.47 “U9” Malfunction of Transmission between Indoor and
Outdoor Units in the Same System ......................................................173
2.48 “UA” Excessive Number of Indoor Units ................................................175
2.49 “UC” Address Duplication of Centralized Remote Controller .................176
2.50 “UE” Malfunction of Transmission between Centralized Remote
Controller and Indoor Unit ....................................................................177
2.51 “UF” Refrigerant System not Set, Incompatible Wiring/Piping ...............179
2.52 “UH” Malfunction of System, Refrigerant System Address Undefined...180
3. Troubleshooting (OP: Central Remote Controller) ..............................181
3.1 “M1” PC Board Defect ............................................................................181
3.2 “M8” Malfunction of Transmission between Optional Controllers
for Centralized Control .........................................................................182
Kommentare zu diesen Handbüchern