INDOOR UNIT FDYQN71FAV1 FDYQN100KAV1 FDYQN125KAV1 FDYQN160KAV1
OUTDOOR UNIT RQ71FV4A RQ100KV4A RQ125KV4A RQ160KV4A
Rated Capacity
Cool (kW) 7.1 10.9 13.5 15.3
Heat (kW) 8.3 11.8 14.2 16.3
Power Input (Rated)
Cool (kW) 2.73 3.97 4.8 5.86
Heat (kW) 3.60 3.50 4.30 4.80
E.E.R./C.O.P. C/H 2.60/2.30 2.75/3.37 2.81/3.30 2.61/3.40
Air Flow Rate (Rated) l/s 560 815 900 1000
Indoor Sound Level (@1.5m) dBA 45 46 48 51
ESP Settings STD/HI STD/HI
Indoor Fan Speeds HI/LO HI/LO
Dimensions
(H x W x D)
Indoor (mm) 360 x 1168 x 869 360 x 1478 x 899
Outdoor (mm) 770 x 900 x 320 1170 x 900 x 320
Weight
Indoor (kg) 48 59 64 66
Outdoor (kg) 65 99
Power Supply Ø/V/HZ 1 phase, 220-240V, 50Hz
Compressor Type Hermetically Sealed, Swing Type Hermetically Sealed, Scroll Type
Refrigerant R410A R410A
Refrigerant Control Electronic Electronic
Refrigerant Pipe Size
Liq (mm) Ø 9.5 (Flared) Ø 9.5 (Flared)
Gas (mm) Ø 15.9 (Flared) Ø 15.9 (Flared)
Drain Pipe Size ID 25mm OD 32mm ID 25mm x OD 32mm
Supply Air Conn. mm 751 x 243 (Flange) 1152 x 243 (Flange)
Return Air Conn. mm 1 x 400 (Oval) 2 x 400 (Oval)
Max Actual Pipe Length m 50 50
Max Level Difference m 30 30
Pre Charged Length m 30 30
Outdoor Operating Range
Cool (°CDB) -5 to 46 -5 to 46
Heat (°CWB) -10 to 15.5 -10 to 15.5
Outdoor Sound Level (H)
@ 1 Metre from front of unit
Pressure dBA (C/H) 49/51 51/55 51/53 52/54
EPA Sound Power Level (dBA) 66 67 - -
FEATURES OF DAIKIN FIXED SPEED
OUTDOOR UNITS
• Daikin’sadvancedcompressordesignsachievefurther
energy savings in both the Swing Compressor (71 class)
and the latest Scroll Compressor (100~160 class).
• SuperAeroGrill–renedventilationmechanismenables
further reduction in required fan power.
• Upto50mofrefrigerantpipingallowsexibilityof
location.
• Certiedoperationdownto-10˚Cinheatingandupto
46˚C in cooling.
• SmoothAirInletBellMouthandAeroSpiralFan–these
two features work to significantly reduce noise. Guides are
added to the bell mouth intake to reduce turbulence in
the airflow generated by fan suction. The Aero Spiral
Fan further reduces turbulence resulting.
FDYQN71FAV1
FDYQN100/125/160KAV1
RQ71FV4A
RQ100/125/160KV4A
INDOOR UNIT OUTDOOR UNIT