MODELS
(4-way Blow Ceiling Suspended type)
FUQ71CVEB
FUQ100CVEB
FUQ125CVEB
INSTALLATION MANUAL
CAREFULLY READ THESE INSTRUCTIONS BEFORE INSTALLATION.
KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE.
LESEN SIE DIESE HINWEISE VOR DER INSTALLATION SORGFÄLTIG DURCH.
BEWAHREN SIE DIESE ANLEITUNG AN EINEM LEICHT ZUGÄNGLICHEN ORT FÜR SPÄ-
TERES NACHSCHLAGEN AUF.
VEUILLEZ LIRE ATTENTIVEMENT CES INSTRUCTIONS AVANT L'INSTALLATION.
CONSERVEZ CE MANUEL EN LIEU SÛR POUR POUVOIR VOUS Y REPORTER
ULTÉRIEUREMENT.
LEA DETENIDAMENTE ESTAS INSTRUCCIONES ANTES DE LA INSTALACIÓN
CONSERVE ESTE MANUAL PARA POSIBLES CONSULTAS FUTURAS.
PRIMA DELL'INSTALLAZIONE, LEGGERE ATTENTAMENTE LE PRESENTI ISTRUZIONI.
CONSERVARE IL PRESENTE MANUALE IN UN LUOGO FACILMENTE ACCESSIBILE PER
RIFERIMENTO FUTURO.
ÄΙΑΒΑΣΤΕ ΠΡΟΣΕΚΤΙΚΑ ΑΥΤΕΣ ΤΙΣ ΟÄΗΓΙΕΣ ΠΡΙΝ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗ
ΦΥΛΑΞΤΕ ΑΥΤΟ ΤΟ ΕΓΧΕΙΡΙÄΙΟ ΣΕ ΒΟΛΙΚΟ ΜΕΡΟΣ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΑΝΑΦΟΡΑ.
LEES DEZE INSTRUCTIES ZOGVULDIG DOOR VOORDAT MET DE INSTALLATIE WORDT
BEGONNEN.
BEWAAR DEZE HANDLEIDING VOOR TOEKOMSTIG GEBRUIK OP EEN GESCHIKTE
PLAATS ONDER HANDBEREIK.
LEIA ATENTAMENTE ESTAS INSTRUÇÕES ANTES DA INSTALAÇÃO.
MANTENHA ESTE MANUAL NUM LOCAL DE FÁCIL ACESSO PARA CONSULTA.
ПЕРЕД УСТАНОВКОЙ ВНИМАТЕЛЬНО ПРОЧИТАЙТЕ ДАННЫЕ ИНСТРУКЦИИ.
ХРАНИТЕ ДАННОЕ РУКОВОДСТВО В ЛЕГКО ДОСТУПНОМ МЕСТЕ ДЛЯ ЕГО
ПОСЛЕДУЮЩЕГО ИСПОЛЬЗОВАНИЯ.
MONTAJDAN ÖNCE BU YÖNERGELERÝ DÝKKATLÝCE OKUYUN.
DAHA SONRA BAKMAK ÜZERE BU KILAVUZU SAKLAYIN.
English
Deutsch
Français
Español
Italiano
Nederlands
Portugues
SPLIT SYSTEM Air Conditioners
00_CV_3P177351-6P.fm Page 1 Sunday, September 30, 2012 4:43 PM
Seitenansicht 0
1 2 3 4 5 6 ... 40 41

Inhaltsverzeichnis

Seite 1 - INSTALLATION MANUAL

MODELS(4-way Blow Ceiling Suspended type)FUQ71CVEBFUQ100CVEBFUQ125CVEBINSTALLATION MANUALCAREFULLY READ THESE INSTRUCTIONS BEFORE INSTALLATION.KEEP TH

Seite 2 - 1. SAFETY PRECAUTIONS

9 English• When carrying the indoor unit, hold it by the hanging metal fittings. (Refer to Fig. 9)How to block the air outlet for 2-way or 3-way air d

Seite 3

English 10(2) Fix the blocking material to the air outlet. (Refer to Fig. 12 and Fig. 13) 1. Insert the projected part (2 places) of the blocking mate

Seite 4 - 2. BEFORE INSTALLATION

11 EnglishFig. 12Drain panLower decoration panelInsulationProjected partBlocking materialProjected partUpper decoration panel2.1.3.1. 2.Insert1.2. 3.B

Seite 5 - 2-2 OPTIONAL ACCESSORIES

English 12*If the blocking material is difficult to insert, loosen the left and right screws of the lower decoration panel and insert it. Make sure to

Seite 6

13 English• Install the indoor unit leveledIf the unit is inclined and the drain piping side gets high, it may cause malfunction of a float switch and

Seite 7

English 14Refrigerant piping can be connected from 3 directions.• In case of upward piping, remove the piping penetration cover, make holes for penetr

Seite 8 - (Refer to Fig. 5 and Fig. 6)

15 EnglishTable 1CAUTIONDo not tighten flare nuts too tight.If a flare nut cracks, the refrigerant may leak.• If there is no torque wrench, use Table

Seite 9

English 16• After leak test, insulate both the gas and liquid piping connection with the attached joint insulating mate-rial (6) and (7) to prevent th

Seite 10

17 English(To prevent small animals and insects getting into the indoor unit, make sure to tightly fit the piping pen-etrating cover to the casing and

Seite 11

English 187. DRAIN PIPING WORK(1) Carry out drain piping.Carry out drain piping so that drainage can ensured.• Drain piping can be connected from 3 di

Seite 12 - 11 English

1 EnglishFUQ71CVEBFUQ100CVEBFUQ125CVEBSPLIT SYSTEM Air Conditioners Installation manualCONTENTS1. SAFETY PRECAUTIONS ...

Seite 13

19 English• Install piping as short as possible with downward inclination of 1/100 or more and without where air may stagnate. (Refer to Fig. 28)(It m

Seite 14 - 6. REFRIGERANT PIPING WORK

English 20If the drain riser is installed inclined, the float switch may malfunction and cause water leakage.• Make sure to use the drain hose (1), th

Seite 15

21 English4. Insulate the metal clamp (2), the drain hose (1), the elbow (10) with the attached sealing material (Large) (8). (Refer to Fig. 25, 26, 2

Seite 16 - R0.4-0.8

English 22[When the electric wiring work is not finished]• The electric wiring works (including earthing) must be carried out by a qualified electrici

Seite 17

23 English• Carry out wiring between the outdoor units, indoor units and the remote controllers according to the wiring diagram.• Carry out installati

Seite 18

English 24Remote controller wiring30-35mmF1P2P1F232160-80mmP2F1P1F220-50mmClamp (4) (accessory)After the wiring are fixed, cut the extra part.< Rem

Seite 19 - 7. DRAIN PIPING WORK

25 EnglishCAUTION FOR WIRING• For connection to the terminal block for indoor-outdoor transmission wiring, use ring type crimp style ter-minals with i

Seite 20

English 26• Keep the distance of 50mm or more between the low voltage wiring (remote controller wiring) and the high voltage wiring (transmission wiri

Seite 21

27 EnglishNOTE1. Terminal numbers of outdoor and indoor units must be matched.2-1. Connect the remote controller only to the master unit.2-2. The remo

Seite 22

English 28< Wiring Method >(1) Remove the control box lid.(2) Connect crossover wiring between the terminals (P1, P2) inside the control box for

Seite 23 - 8. ELECTRIC WIRING WORK

English 2• Be sure to use only the specified parts and accessories for installation work.Failure to use the specified parts may result in the air cond

Seite 24 - Fig. 36)

29 EnglishNOTE• Terminal numbers of outdoor and indoor units must be matched.8-5 FOR CENTRALIZED CONTROL• By connecting the centralized control equipm

Seite 25 - (Sheath peeling

English 309. MOUNTING CORNER COVER · SUCTION GRILLE〈〈For test operation without the corner cover, first refer to “11. TEST OPERATION”〉〉• For backward

Seite 26 - Insulation sleeve

31 English• Hook the strap (b) for preventing the suction grille from falling. (Refer to Fig. 49-(3))10. FIELD SETTINGCAUTIONBefore carrying out field

Seite 27

English 32• Though the indoor unit is equipped with the long life filter, it is necessary to periodically clean the filter to avoid clogging of the fi

Seite 28 - 123 123 123

33 English10-6 SIMULTANEOUS OPERATION SYSTEM INDIVIDUAL SETTINGIt is easier if the optional remote controller is used when setting the slave unit.<

Seite 29 - F2P2 F1P1P2P1 F1 F2

English 3411. TEST OPERATION<Complete all the “1. Items to be checked after the installation work is completed” on page 4. Please also refer to the

Seite 30 - P1 P2 F1 F2

35 English2. With the wireless remote controller. (Also refer to the operation manual attached to the wireless remote controller)When the operation st

Seite 31

English 36C6Fan motor Printed Circuit Board setting errorC9 Suction air thermistor malfunctionAbnormal stop is applied depending on the model or condi

Seite 32 - 10. FIELD SETTING

37 EnglishJADischarge piping pressure sensor system malfunction (Outdoor unit)JCSuction piping pressure sensor system malfunction (Outdoor unit)L1Inve

Seite 33

English 38CAUTIONAfter test operation is completed, check the items mentioned in the clause 2 “2. Items to be checked at delivery” on page 4.If the in

Seite 34

3 English2. BEFORE INSTALLATIONWhen unpacking the indoor unit or moving the unit after unpacked, hold the hangers (4 places) and do not apply force to

Seite 35 - 11. TEST OPERATION

39 English3P326999-1 FUQ71 • 100 • 125CVEBSELECTOR SWITCH (MAIN/SUB)SELECTOR SWITCH(WIRELESS ADDRESS SET)SS1SS2PRINTED CIRCUIT BOARDPRINTED CIRCUIT BO

Seite 36 - 11-2 MALFUNCTION CODE

(1209) HT3P177351-6P EM12A00200_CV_3P177351-6P.fm Page 2 Sunday, September 30, 2012 4:43 PM

Seite 37

English 42-2 OPTIONAL ACCESSORIES• For this indoor unit, the remote controller is separately required.(Note that the remote controller is not required

Seite 38

5 EnglishPoints of the operation explanation3. SELECTION OF INSTALLATION LOCATIONHold the hangers at 4 places to move the indoor unit when unpacking o

Seite 39 - 12. WIRING DIAGRAM

English 6CAUTION• Install the indoor and outdoor units, power supply wiring, remote controller wiring and transmission wiring at least 1 meter away fr

Seite 40 - WIRING DIAGRAM

7 English4. PREPARATION BEFORE INSTALLATION(1) Check the locations of indoor unit hanging bolts, piping outlet holes, drain piping outlet hole and ele

Seite 41 - 3P177351-6P EM12A002

English 8(2) Make holes for hanging bolts, piping outlet, drain piping outlet and electric wiring inlet.• Use the installation pattern paper (11) whic