Daikin FFQ25BV1B Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Split-System-Klimaanlagen Daikin FFQ25BV1B herunter. Split Sky Air Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - (600mm x 600mm)

FFQ-B4-way Blow CeilingMounted Casette(600mm x 600mm)technical data SplitSky Airair conditioning systems

Seite 2 - Split - Sky Air

6Sound level6-1Sound level dataLocation of microphoneModelSound pressure levelSound power level (H)230V, 50HzMeasuring locationHLFFQ25BV1B 29.5 24.5 4

Seite 3 - TABLE OF CONTENTS

6Sound level6-2Sound pressure spectrumOctave band sound pressure leveldB:(0dB = 0.0002 µ bar)Octave band sound pressure leveldB:(0dB = 0.0002 µ bar)Oc

Seite 4 - Optional Optional Optional

7Air flow patternsFFQ25BCooling - air velocity distribution4-way discharge air flow direction: horizontalFFQ25BCooling - air velocity distribution4-wa

Seite 5 - Specifications

FFQ25BHeating - air velocity distribution4-way discharge, air flow direction: downFFQ25BHeating - air temperature distribution4-way discharge, air flo

Seite 6

FFQ35BCooling - air velocity distribution4-way discharge air flow direction: horizontalFFQ35BCooling - air velocity distribution4-way discharge air fl

Seite 7 - Dimensional drawings

FFQ35BHeating - air velocity distribution4-way discharge, air flow direction: downFFQ35BHeating - air temperature distribution4-way discharge, air flo

Seite 8 - FFQ50 - 60BV1B 6.4 12.7

FFQ50BCooling - air velocity distribution4-way discharge air flow direction: horizontalFFQ50BCooling - air velocity distribution4-way discharge air fl

Seite 9 - Wiring diagrams

FFQ50BHeating - air velocity distribution4-way discharge, air flow direction: downFFQ50BHeating - air temperature distribution4-way discharge, air flo

Seite 10 - Sound level

FFQ60BCooling - air velocity distribution4-way discharge air flow direction: horizontalFFQ60BCooling - air velocity distribution4-way discharge air fl

Seite 11

FFQ60BHeating - air velocity distribution4-way discharge, air flow direction: downFFQ60BHeating - air temperature distribution4-way discharge, air flo

Seite 12 - 4D039738A

Split - Sky AirEEDE03-1/2 • 03/2003Prepared in Belgium by Goekint GraphicsZandvoordestraat 300B - 8400 Ostend BelgiumInternet: http://www.daikineurope

Seite 13 - 4D039820A

8Accessories8-1Standard accessoriesNamej1Drain hosej2Clampj3Washer for hanging bracketj4Clampj5Paper pattern for installationQuantity 1 pc. 1 pc. 8 pc

Seite 14 - 4D039816

8Accessories8-2Optional accessoriesName of option Remark FFQ25BV1B FFQ35BV1B FFQ50BVB FFQ60BV1BDecoration panel BYFQ60BW1Sealing member of air dischar

Seite 15 - 4D039846

9Control systems9-1Wired remote controlFigure 1Remote controlBRC1C517BRC1C517Notavailable6.5 x 9 (Round end slit)Figure 2Cover openCover closed5 x 7 (

Seite 16 - 4D039815

Name and function of each switch and display onthe remote control1ON/OFF BUTTONPress the button and the system will start. Press the button again and

Seite 17 - 4D039848

9Control systems9-2Infrared remote control kitFFQ-BTransmitting partRemote control dimensions Receiver installation procedureDrain piping sideRefriger

Seite 18 - 4D039733

10Safety device settingsModel Safety devices 25 35 50 60FFQ-BV1BFuse 250V 5A 250V 5A 250V 5A 250V 5AFan motor thermal protector (°C)OFF: 130±5ON: 83±2

Seite 19 - 4D039849

11InstallationNOTES1 Line voltage wiringControl circuit wiring2 All wiring, components and materials to be produced on the site must comply with theap

Seite 20 - Accessories

TABLE OF CONTENTSFFQ-B1 Features ... 22 Specifications...

Seite 21

1Features+ Leaves maximum floor and wall space for furniture, decorationand fittings+ Fits flush into each ceiling thanks to the new and very compactc

Seite 22 - Control systems

2SpecificationsNOMINAL CAPACITY and NOMINAL INPUTFor indoor units only:INDOOR UNITS FFQ25BV1B FFQ35BV1B FFQ50BV1B FFQ60BV1BINPUT Coolingmin.∼nom.∼max.

Seite 23

ELECTRICAL SPECIFICATIONSFor indoor units only: FFQ25BV1B FFQ35BV1B FFQ50BV1B FFQ60BV1BCURRENT Nominal running current A 0.37 0.40 0.49 0.61Max. runni

Seite 24

3Dimensional drawingsFFQ25-35BA Arrow view533 Suspension position533 (Suspension position)585∼660 (Ceiling opening)Note:1. Sticking location for manuf

Seite 25 - Installation

4Piping diagramsO Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe P Spinned pipeIndoor heat exchangerField piping

Seite 26

5Wiring diagrams3D038357BFFQ-BA1P Printed circuit boardC1 Capacitor (M1F)F1U Fuse (F5A 250V)HAP Light emitting diode (service monitor green)KPR Magnet