—suitable for homes, offices, shops, and middle-sized buildings
Cooling Only 50 Hz
Single outdoor unit series
VRV indoor units combine with
residential indoor units, all in one system
PCV1131
Seitenansicht 0
1 2 3 4 5 6 ... 47 48

Inhaltsverzeichnis

Seite 1 - Single outdoor unit series

—suitable for homes, offices, shops, and middle-sized buildings Cooling Only 50 HzSingle outdoor unit seriesVRV indoor units combine with residential

Seite 2 - Meet the new single outdoor

9360° airflow improves temperature distributionand offers a comfortable living environment.FXFQ25P/FXFQ32P/FXFQ40PFXFQ50P/FXFQ63P/FXFQ80PFXFQ100P/FXFQ

Seite 3 - Contents

10 Quiet, compact, and designed for user comfortDimensions correspond with 600 mm X 600 mm architectural module ceiling design specifications. Wide di

Seite 4 - Wide range of choices

11Thin, lightweight, and easy to install in narrow ceiling spacesFXCQ-M 2032/2725/3234/286337/3240/5034/298039/3412544/3834/29 36/30 39/3437/32 41/36

Seite 5 - Outdoor units

12Slim design for flexible installationMain bodyAir discharge grille (Option)Set for front discharge using a suspended ceiling.Downward discharge is s

Seite 6 - High COPs

Indoor Unit LineupVRV Indoor UnitsSlim Ceiling Mounted Duct Type13* Remote controllers are an optional accessory. Refer to page 39 for remote control

Seite 7 - Heat exchanger

Ceiling Mounted Duct Type14* Remote controllers are an optional accessory. Refer to page 39 for remote controller details.Middle and high static pres

Seite 8 - Design flexibility

Indoor Unit LineupVRV Indoor UnitsCeiling Suspended Type15Slim body with quiet and wide airflowAdoption of QUIET STREAM FAN Drain pump kit (option) ca

Seite 9 - Residential indoor units

Wall Mounted Type16Sophisticated design and compact casing harmonised with your interior décorDrain pan and air filter can be kept clean by mildew-pro

Seite 10 - FXFQ100P/FXFQ125P

Indoor Unit LineupVRV Indoor UnitsFloor Standing Type17Suitable for perimeter zone air conditioningWall hangingFloor installationFloor Standing types

Seite 11 - FXZQ40M/FXZQ50M

Ceiling Suspended Cassette Type18Connection unit series indoor unitsFXUQ71MA/FXUQ100MAFXUQ125MAThis thin indoor unit achievesoptimum air distribution,

Seite 12 - FXCQ80M/FXCQ125M

11Meet the new single outdoor unit series, connectable to both VRV and residential indoor unitsFirst launched in Japan in 1982, the Daikin VRV system

Seite 13 - FXKQ40MA/FXKQ63MA

Indoor Unit LineupResidential Indoor Units19FCQ35B/FCQ50B/FCQ60B/FCQ71BOptionOptionSignal receiver unitNote: Remote controller cables not included. Ca

Seite 14 - Slim design, quietness and

20Quiet, compact, and designed for user comfortT-bar grid does not need to be cut.Designed to fit 600 mm wide ceiling gridsLow draft performance is de

Seite 15 - Indoor unit

Indoor Unit LineupCeiling Mounted Built-in Type21FBQ60B41/35 dB (A)FBQ71B41/35 dB (A)(H/L)The indoor unit can be installed in rooms with as little as

Seite 16 - FXHQ100MA

Slim Ceiling Mounted Duct Type22Slim and smooth design suits your shallow ceiling700 mm width type900/1,100 mm width typeSignals from the wireless rem

Seite 17 - FXAQ50MA/FXAQ63MA

Indoor Unit LineupWall Mounted Type23Wall Mounted indoor units achieve quiet sound levels of 22 dB (A).Intelligent Eye with its infrared sensor automa

Seite 18

24Ceiling Mounted Cassette (Round Flow) TypeFXFQ25PVE2.99,9002,500Galvanised steel plate246X840X84019.5 6.4 12.7VP25 (External Dia, 32/Internal

Seite 19 - BEVQ71MA/BEVQ100MA/BEVQ125MA

25Ceiling Mounted Cassette Corner TypeCeiling Mounted Cassette (Double Flow) TypeFXKQ25MAVE2.99,9002,500Galvanised steel plate11/9FXKQ32MAVE3.712,6003

Seite 20 - Ceiling Mounted Cassette Type

26Slim Ceiling Mounted Duct Type (700 mm width type)Galvanised steel plate7,8002,0009,9002,50012,6003,2002.20.086 0.086 0.0898.0/7.2/6.4282/254/2268.0

Seite 21 - FFQ25B/FFQ35B/FFQ50B/FFQ60B

27Ceiling Mounted Duct TypeNote: Specifications are based on the following conditions;•Cooling: (*1) Indoor temp. of 27°CDB, 19.5°CWB, and outdoor tem

Seite 22 - 41/35 dB (A)

28Ceiling Mounted Duct TypeCeiling Suspended TypeFXMQ200MAVE FXMQ250MAVE23.078,50019,80028.822.4 28.098,30024,8001-phase, 220-240 V/220 V, 50/60 HzMOD

Seite 23 - FDKS25EA/FDKS35EA

2HOMESOFFICESSHOPSContentsMain Features...page 3Control Systems...page 39Indoor Unit Lineup...

Seite 24 - Air filter

29Wall Mounted TypeFXAQ25MAVE2.9White (3.0Y8.5/0.5)36/29290X795X23011.0Casing1-phase, 220-240 V/220 V, 50/60 Hz37/29290X795X23011.0FXAQ40MAVE4.739/342

Seite 25

30Ceiling Suspended Cassette TypeConnection unit series indoor units* A type of BEV unit is necessary for each Connection unit series indoor unit. Ref

Seite 26

31 Ceiling Mounted Cassette (Compact Multi Flow) Type1-phase, 220-240 V/220 V, 50/60 Hz2 stepsFCQ71BVE35/3019.0 (671)ø9.5ø15.9FCQ60BVEFCQ50BVE15.0 (53

Seite 27 - (900/1,100 mm width type)

321-phase, 220-240 V, 50 Hz2 steps41/35FBQ71BV119.0 (670)FBQ60BV117.0 (600)ø9.5ø6.4ø15.9ø12.7MODELPower supplyBoth liquid and gas pipesHeat insulation

Seite 28 - Ceiling Mounted Duct Type

33 1-phase, 220-240 V/220 V, 50/60 HzBPMKS967B2BBPMKS967B3BMODELPower supply3 (connectable to 1-3 indoor units) 2 (connectable to 1-2 indoor units)N

Seite 29

34Specifications—Indoor Units•Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.

Seite 30

35Ceiling Mounted Cassette (Round Flow) TypeCeiling Mounted Cassette (Double Flow) TypeNo. 12Decoration panelHigh efficiency filter 65% 1 High effic

Seite 31

36Ceiling Suspended TypeWall Mounted TypeFXAQ25MAFXAQ20MA1 Drain pump kit K-KDU572EVEFXAQ32MA FXAQ40MA FXAQ50MA FXAQ63MANo. TypeItemFloor Standing Typ

Seite 32

37Ceiling Mounted Cassette TypeFCQ35BVE FCQ50BVE FCQ60BVE FCQ71BVE14BYC125K-W1High-efficiency filterDecoration panel2 KDBP55H160WAPanel spacer 3KDDP55

Seite 33 - Ceiling Mounted Built-in Type

38BPMKS967B2B1 REFNET joint KHRP26A22TBPMKS967B3BNo. TypeItemFTKS35DVMFTKS25DVM1 Titanium apatite photocatalytic air-purifying filter KAF970A46FTKS50F

Seite 34 - BPMKS967B2BBPMKS967B3B

Wide range of choicesMain Features3VRV indoor units15 types 73 modelsVRV indoor unitsCeiling MountedCassette (Round Flow)TypeModel NameCapacity RangeC

Seite 35 - Outdoor unit combinations

39Control SystemsIndividual Control Systems for VRV Indoor UnitsLarge buttons and arrow keys for easy operation.Guide on display gives an explanation

Seite 36

40Wireless remote controller (Option)Wired remote controller(BRC1C62)Wired remote controller with weekly schedule timer(BRC1D61) Wireless remote contr

Seite 37

Control Systems41Up to 64 groups of indoor units (128 units) can be centrally controlled.Optional controllers for centralised control can be combined

Seite 38

42Max. 16 groups of indoor units can be easily controlled with the large LCD panel.• Max. 16 groups (128 indoor units) controllable• Backlight and lar

Seite 39

—— — DTA114A61 DTA114A61 DTA114A6143Operation Control System Optional AccessoriesFor VRV indoor unit useFor Residential indoor unit useNo. FXFQ

Seite 40 - Control Systems

44System Configuration•Up to 64 groups of indoor units(128 units) can be connected, and ON/OFF, temperature setting and monitoring can be accomplished

Seite 43 - (Option)

1. Air conditioners should not be installed in area s where corrosiv e gas es, suc h as acid gas or alkalin e gas, are produced.2. If the outdoor un

Seite 44 - Option List

Wall MountedSlim CeilingMounted DuctCeiling MountedCassette (Compact Multi Flow)TypeModel NameRated Capacity2.5 kW 6.0 kW 7.1 kW5.0 kW3.5 kWCapacity I

Seite 45 - Building Management System

Energy efficiency and quiet operationMain Features5Nighttime quiet operation functionSet on the outdoor PCB. Time of maximum temperature is memorised.

Seite 46

A collection of cutting-edge technologiesrealises efficient and quiet operation15DC fan motor3Compact aero boxRealises a compact casing by stacking th

Seite 47

Design flexibilityMain FeaturesLong piping length offers flexibility during installation.When only VRV indoor units are connectedWhen only VRV indoor

Seite 48 - Cautions on product corrosion

Easy Installation High reliabilityHigh external static pressure of 78.4 PaHigh external static pressure has been achieved thanks to the fan grilles an