Seitenansicht 9
10
Benets
overview
We care iconsComfortAir ow
Humidity
control
Air treatment
Remote control & timerOther functions
Econo mode
Decreases the power consumption so that other applicances that need large power
consumption can be used.
2-area intelligent eye
Air ow is sent to a zone other than where the person is located at that moment. Detection is
done in 2 directions: left & right. If no people are detected, the unit will automatically switch
over to the energy-ecient setting.
35,42,50
class
35,42,50
class
35,50
class
3
3- area intelligent eye
Air ow is sent to a zone other than where the person is located at that moment. Detection is
done in 3 directions : left, front and right. If no people are detected, the unit will automatically
switch over to the energy-ecient setting and eventually switches o.
Movement sensor
The sensor detects whether someone is in the room. When the room is empty, the unit
switches to economy mode after 20 minutes and restarts when a person enters the room.
20,25
class
20,25
class
20,25
class
Energy saving during operation
standby
Current consumption is reduced by about 80% when operating on standby.
Home leave operation During absence, the indoor temperature can be maintained at a certain level.
Night set mode Saves energy, by preventing overcooling or overheating during night time.
Fan only The air conditioner can be used as fan, blowing air without cooling or heating.
Auto cleaning lter
The lter automatically cleans itself once per day. Simplicity of upkeep means optimum
energy eciency and maximum comfort without the need for expensive or time-consuming
maintenance.
Comfort mode
The unit automatically changes the angle of the air discharge louvre depending on the mode.
In cooling operation the air will be directed rather upwards to avoid cold draught, while in
heating operation the air will be directed rather downwards to avoid cold feet.
Powerful mode
If the temperature in the room is too high/low, it can be cooled down/heated quickly by
selecting the powerful mode’. After the powerful mode is turned o, the unit returns to the
preset mode.
Auto cooling-heating changeover Automatically selects cooling or heating mode to achieve the set temperature
Whisper quiet (down to 19dBA) With sound levels as low as 19dBA, Daikin units are whisper quiet.
Indoor unit silent operation
To ensure a quiet environment for studying or sleeping the user can lower the operation
sound of the indoor unit by 3dB(A) via remote control.
Comfortable sleeping mode Increased comfort function that follows a specic temperature uctuation rhythm.
Outdoor unit silent operation
To ensure a quiet environment for the neighbourhood the user can lower the operation
sound of the outdoor unit by 3dB(A) via remote control.
3-D Air ow
This function combines Vertical and Horizontal auto-swing to circulate a stream of cool/warm
air right to the corners of even large spaces.
35,42,50
class
35,42,50
class
35,50
class
Vertical auto swing
Possibility to select automatic vertical moving of the air discharge louvre, for uniform air ow
and temperature distribution.
Horizontal auto swing
Possibility to select automatic horizontal moving of the air discharge louvre, for
uniform air ow and temperature distribution.
35,42,50
class
35,42,50
class
35,50
class
Auto fan speed
Automatically selects the necessary fan speed to reach or maintain the set
temperature.
Fan speed steps Allows to select up to the given number of fan speed. 5 5 5 5 5 5 5 5 5 5 5 5 3 3 5 5 5 3 3 5
Ururu - humidication
Moisture is absorbed from the outdoor air and evenly distributed throughout the indoor
areas.
Sarara - dehumidication
Reduces indoor humidity, without aecting the room temperature, by mixing cool, dry air
with warm air.
Dry programme Allows humidity levels to be reduced without variations in room temperature
Flash streamer
The Flash Streamer generates high-speed electrons that powerfully break down
odours and formaldehyde
Titanium photocatalytic air
purication lter
Removes airborne dust particles and decomposes the odour of for example tobacco and
pets. It also decomposes harmful organic chemical substances such as bacteria, viruses and
allergens.
Air lter Removes airborne dust particles to ensure a steady supply of clean air.
Online controller via app Control your indoor unit from any location via app. (optional WLAN adapter)
Weekly timer Timer can be set to start operation anytime on a daily or weekly basis
24 Hour timer Timer can be set to start cooling/heating anytime during a 24-hour period.
Infrared remote control
Infrared remote control with LCD to start, stop and regulate the air conditioner from a
distance.
Wired remote control Wired remote control to start, stop and regulate your indoor unit from a distance.
Centralised remote control Centralised control to start, stop and regulate several indoor units from one central point.
Auto-restart The unit restarts automatically at the original settings after power failure.
Self-diagnosis Simplies maintenance by indicating system faults or operating anomalies.
Multi model application
Up to 5 indoor units (even dierent capacities) can be connected to a single outdoor unit.
All indoor units can individually be operated within the same mode.
VRV for residential application
Up to 9 indoor units (even dierent capacities and up to 71 class) can be connected
to a single outdoor unit. All indoor units can individually be operated within the
same mode.
-2
Guaranteed operation down to -25°C
Daikin heat pumps are suitable for all climates, even withstanding severe winter conditions
with an operation range down to -25°C
with RXLG-M
Wall mounted
Wall mounted
FTXZ-N
FTXJ-LW/S
FTXG-LW/S
FTXM-K
CTXS-K FTXS-K FTXLS-K FTXS-G FTX-J3 FTXL-JV FTX-GV FTX-K FTXK-AW/S FTXB-C ATXS-K ATXL-JV ATX-J3 ATX-K ATXB-C ATXN-NB