Daikin BRC7C62 Bedienerhandbuch Seite 12

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 19
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 11
7 English
On AUTOMATIC OPERATION
In this operation mode, COOL/HEAT
changeover is automatically conducted at a
present indoor temperature.
Press ON/OFF button.
OPERATION lamp lights up and the system
starts OPERATION.
〈〈FOR SYSTEMS WITH COOL/HEAT
CHANGEOVER REMOTE CONTROL
SWITCH (Fig. 4)〉〉
Select OPERATION MODE with
the COOL/HEAT
CHANGEOVER REMOTE CONTROL
SWITCH as follows.
COOING OPERATION ....................
Refer to fig. 4-1 ( , )
HEATING OPERATION ...................
Refer to fig. 4-2 ( , )
FAN OPERATION ............................
Refer to fig. 4-3 ( )
Press ON/OFF button.
OPERATION lamp lights up and the system
starts OPERATION.
ADJUSTMENT
For programming TEMPERATURE and FAN
SPEED and AIR FLOW DIRECTION, follow
the procedure shown below.
Press TEMPERATURE SET-
TING button and program the
setting temperature.
Each time this button is pressed,
setting temperature rises 1°C.
Each time this button is pressed,
setting temperature lowers 1°C.
In case of automatic operation
Each time this button is pressed, set-
ting temperature shifts to “H” side.
Each time this button is pressed, set-
ting temperature shifts to “L” side.
2
1
2
3
UP
DOWN
UP
DOWN
[°C]
Note:
The setting is impossible for fan operation.
Press FAN SPEED CONTROL
button.
High or Low fan speed can be selected.
Press AIR FLOW DIRECTION
button.
Refer to “ADJUSTING THE AIR FLOW
DIRECTION” (p. 9) for details.
STOPPING THE SYSTEM
Press ON/OFF button once
again.
OPERATION lamp goes off, and the system
stops OPERATION.
NOTE
Do not turn OFF power immediately after
the unit stops. Then, wait no less than
5 minutes. Water is leaking or there is
something else wrong with the unit.
[EXPLANATION OF HEATING
OPERATION]
DEFROST OPERATION
As the frost on the coil of an outdoor unit
increase, heating effect decreases and the
system goes into DEFROST OPERA-
TION.
The fan operation stops and the
DEFROST lamp of the indoor unit goes on.
After 6 to 8 minutes (maximum 10 min-
utes) of DEFROST OPERATION, the sys-
tem returns to HEATING OPERATION.
Heating capacity & Outdoor air tem-
perature
Heating capacity drops as outdoor air tem-
perature lowers. If feeling cold, use
another heater at the same time as this air
conditioner.
H•ML
Setting
temperature
25 23 22 21 19
4
5
6
01_EN_3P107422-22S.fm Page 7 Tuesday, June 3, 2008 4:51 PM
Seitenansicht 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 18 19

Kommentare zu diesen Handbüchern

Keine Kommentare