IM 796 Page 1Installation and Maintenance Manual IM796Group: UnitaryPart Number: IM796Date: March 2005© 2005 DaikinMWM Wall Mounted Split Type Air
Page 10 IM 796Wiring DiagramsMAIN BOARDS1CN5SWITCH BOARDDISPLAY BOARDCN4IR_RCVINDOOR COIL THERMISTORROOM THERMISTORROOMCN3IDCOMPCN1NCN2T315ANORANGE (
IM 796 Page 11MAIN BOARDS1CN5SWITCH BOARDDISPLAY BOARDCN4IR_RCVINDOOR COIL THERMISTORROOM THERMISTORROOMCN3IDCOMPCN1NCN2T315ANORANGE (LO)BROWN (MED)
Page 12 IM 796MAIN BOARDROOM THERMISTORT3 15AORANGE (LO)BLACK (HI)INDOOR COIL THERMISTORASIDODCN12COMPCOMPSGREEN/YELLOWOLOPTIONALNETWARE 2CONTROLLERN
IM 796 Page 13MAIN BOARDROOM THERMISTORT3ORANGE (LO)BLACK (HI)COMPINDOOR UNIT - 208/230V/1/60MODEL : MWM 10FR - 15FRYELLOW/GREENINDOOR COIL THERMIST
Page 14 IM 796MAIN BOARDROOM THERMISTORIDT3.15AORANGE (LO)BLACK (HI)COMPINDOOR UNITMODEL : MWM 20FR - 25FRYELLOW/GREENASINDOORCOILTHERMISTOROPTIONALN
IM 796 Page 15CMOFCSRCAPACITORCAPACITORWHITEREDBLUE BLUEBLUEBLUEREDBROWNCOMPNGREEN/YELLOWNOTATIONCM - COMPRESSOR MOTOROF - OUTDOOR FANOL - OVERLOADF
Page 16 IM 796Evacuating and ChargingEvacuating the tubing and the indoor unitThe outdoor unit is pre-charged with refrigerant R-22. Theindoor unit a
IM 796 Page 17Unit Indicator LightsIR signal receiverWhen an infrared remote control operating signal is transmit-ted, the signal receiver on the in
Page 18 IM 796Table 7: LED Indicator Lights: Normal Operation and Fault Conditions for Heat Pump Unitt ON ON or OFF Blinking* Unit has 10 minute de
IM 796 Page 19Special FeaturesDry mode• Select this mode when the standard Cool mode does notprovide sufficient dehumidification. The compressor and
Page 2 IM 796Table of ContentsGeneral Information ... 3Safety Precautions ...
Page 20 IM 796Figure 22. Installing FiltersFilter ReplacementReplace the electrostatic air purifying and deodorizing filtersevery 6 months or sooner
IM 796 Page 21Remote Controller Operation GuideSymbol IdentificationTransmission source• The source where the signal istransmitted.ON Timer Setting•
Page 22 IM 796Netware 2 - Optional Wired Wall Control (Heat Pump Only)Features:1. Modes - Cool, Heat, Auto, Dry, Fan and Off.2. Temperature Range - 6
IM 796 Page 23Service and MaintenanceMaintenance ScheduleTroubleshootingIf any malfunction of the unit is noted, immediately switch off the power su
© 2004 DaikinThis document contains the most current product information as of this printing. For the most up-to-date product information, please go
IM 796 Page 3General InformationThis manual provides the installation procedures so your air conditioner unit operates properly and pro-vides you th
Page 4 IM 796Unit DimensionsIndoor UnitsModel: MWM10F, 10FR, 15F, 15FRModel: MWM20F, 20FR, 25F, 25FR32"7-1/8"11-1/2"10-7/8"1/2&qu
IM 796 Page 5Outdoor UnitsModel: MLC10B, 10BR, 15B, 15BRModel: MLC20B, 20BR, 25B, 25BRFRONT VIEWSIDE VIEWTOP VIEWELECTRICAL ACCESS PANELWITH 7/8&quo
Page 6 IM 796Installation GuidelinesInstallation DiagramInstallation of Outdoor UnitOutdoor Unit ClearancesInstall the outdoor unit in a manner to pr
IM 796 Page 7Mounting Plate Installation The mounting plate ships attached to the back of the indoorunit. To detach for mounting on wall, remove pla
Page 8 IM 796Refrigerant TubingTubing Length & ElevationCopper tubing to connect the indoor and outdoor units is sup-plied by others or it can be
IM 796 Page 9Electrical Connections• Wiring must be in accordance with all applicable electri-cal codes.• Wires must not touch the refrigerant pipin