SiENBE81-623A Operation Manual
Photocatalytic Air Purifiers 15
4
123 13 15
14121110987654
”“ ”“
”“
Main unit display
1 Air intake for dust sensor
Air is taken in from here and the dust sensor detects the dirty state
of the air.
2 Clean monitor (Dust)
Detects the dirty state of the air and indicates the results.
In the following case, only the green light is on for the first
7 seconds regardless of pollution from the air.
Operation directly after setting the front panel or plasma ionizer
Operation directly after inserting the power plug
• You can change sensitivity setting of the dust sensor lamp.
3 Clean monitor (Odor)
Detects changes to odors and indicates the results.
• Reactions to sudden temperature/humidity changes and odorless
gas (carbon monoxide) may occur.
• There may not be any reaction for a uniform case without any
changes to the intensity of the odor.
• There may be no reaction to pet odors or garlic odors.
Different people have different sensitivity to odors so yo
u may not
notice an odor even though the lamp is green.
In the following case, only the green light is on for the first
1 minute and this state is regarded as the reference value of the
odor sensor.
Operation directly after setting the front panel or plasma ionizer
Operation directly after inserting the power plug
4 Automatic operation indicator (yellow)
Lit during automatic operation.
5 Airflow rate indicator (green) (page 7.)
Lit by the set airflow rate setting.(The air volume lamp is on during
automatic or manual operation.)
6 Turbo mode indicator (green) (page 7.)
Lit during turbo mode.
7 Anti-pollen mode indicator (page 7.)
Lit during pollen mode.
8 Negative ion mode indicator (page 7.)
Indicates during negative ion operation.
9 OFF timer setting indicator (yellow) (page 7.)
Indicates the set OFF timer time.Indicates the remaining time after
setting as the time passes.
10
Clean indicator (red) (pages 11, 12.)
The lamp will blink for cleaning time of the plasma ionizer.
11
Replace indicator (red) / Reset button
The lamp will be on for replacement time of the pleated filter and
blink after certain time has elapsed from the turning on.
*Press the
reset button after replacement. (page 10.)
12 Lock lamp (page 7.)
Lit during lock.
13 Air intake for odor sensor
Air is taken in from here and the odor sensor detects the odor state.
14 Receiver
Receives signals from the remote control.
15 Operation switch / stop button
Each time this button is pressed, the operation mode switches as
shown below.
* During automatic operation the airflow rate at that time will also be
lit.
Dust Indicator Off On
Low
High
Red Yellow Green
Yellow Green
Green
Odor Indicator Off On
Weak
Strong
Green Yellow Red
Green Yellow
Green
(Automatic) LL (Quiet) L (Low) M
(Standard)
(Stop)
(Pollen) HH (Turbo) H (High)